Spencers Ultra Low Temperature Freezers maintain internal temperatures as low as -86°C (-123°F). All models use SPENCERS uniquely designed compressors for ultra-low temperature applications. Manufactured with foamed-in-place insulation, they are ideally suited for use in laboratories and hospitals for long-term preservation and storage of blood, specimens and components, as well as materials testing.
Advanced features include a microprocessor temperature control system with digital temperature display, a power failure warning system with built-in audible and visible indicators, double insulation polyurethane walls and easy open/ easy-close hinged outer door latch.
CFC-Free
SPENCERS Refrigerators feature commercially available CFC-free, HFC refrigerants and CFC-free insulation.
CPU and Touch Pad (Optional)
The computer control system designed for low-temperature application ensures accurate setting with touch-pad switches.
LED Digital Display
The strategically located LED digital display is easy to read.
Quiet, Reliable Compressor
Designed by SPENCERS specifically for demanding ultra-low temperature applications in a laboratory environment.
Rechargeable Battery
A rechargeable battery is built in as the backup battery for alarms.
Insulated Inner Doors
SPENCERS unique doors are fully insulated to provide better uniformity and guarantee an airtight seal. Inner doors ensure that exposure to incoming air is kept to a minimum when the outer door is opened. Doors are latched.
Cascade Cooling System
At the heart of freezers that are as efficient and reliable as SPENCERS freezers is the SPENCES designed cascade cooling system. SPENCERS experience in ultra-low temperature technology has made the compact, quiet and reliable refrigeration system possible.
Air Filter
The air filter is specially located to give easy access for removal. The filter also is washable for economy and do-it-yourself maintenance.
Castors
Mounted on wheeled casters to make moving easy.
Energy Efficient
The combination of efficient technology and construction brings the added benefit of considerable energy savings.
Power Failure Alarm
The backup battery sounds the alarm in the event of power failure, AC interruption or other abnormality.
Automatic System
Provides both an audible and visual temperature alarm when the temperature increases to more than 5°C to 15°C (adjustable) from the setpoint.
FEATURE SELECTIONS
LCD / TFT Display .
Temperature data logger.
Temperature Chart Recorder.
Computer Interface & software.
Data store memory & print function.
Alarm system with rechargeable battery backup. Alarms for open door, sensor fault, condenser fault etc.
Voltage safety system.
TECHNICAL SPECIFICATION |
Model No. |
1180-SFR-091 |
1180-SFR-092 |
1180-SFR-093 |
And More…… |
Temp. Range |
-50 to -86 degrees C |
Capacity |
100 Liters |
200 Liters |
500 liters |
As Required. |
Controller |
Microprocessor / Micro-controller based temperature controller |
Temperature Display |
Digital LED/LCD |
High & Low Alarm |
Audio-visual high & low temperature alarm |
Low Temperature Freezer Construction |
Outer Panels |
Outer panels are made of GI coated/ CPRCA sheet/Stainless Steel |
Interior Panels |
Interior panels are made of Stainless Steel |
Door |
Standard front hinged lockable single/double door unit with stainless steel panel & Triple point Silicon Gasket seal between the door and the cabinet increases system efficiency. |
Insulation |
Polyurethane foam insulation with a thickness of 120mm |
Compartments |
Individual Compartments made up of PVC and outer door made up of Galvanized sheet duly finished with epoxy paint. |
Trays |
Adjustable stainless steel trays with perforated design |
Castors |
Castors for minimal effort mobility. |
Heater Harness |
Heater harness provides a dry exterior cabinet. Heater prevents condensation of moisture and is located under the channel cap which is between the lid and body of the cabinet. |
Low Temperature Freezer Refrigeration system |
Refrigeration system |
SPENCERS superior refrigeration system with optional Backup refrigeration system. |
Compressor |
Heavy duty dual compressors. The low stage compressor cycles off when the set
point temperature is reached and the high stage compressor runs continuously enabling reduced power consumption, extends life, protects the thermal overload system, decreases noise levels and provides dependable and stable cooling. The compressor is distinguished by its excellent performance, low noise level and minimal vibration. |
Condenser |
Highly efficient, high capacity air cooled condenser with automatic condensate evaporating system. Dual condenser fans and aerodynamically shaped fan blades. Copper tubing with High side fin tube and low side shell tube design. |
Evaporator |
Tube on sheet type. Cooling-coils-in-the shelf design with cooling coils in direct contact with sample provides rapid freezing, improved sample temperature uniformity. |
Oil Separator |
Oil separator effectively separates the lubricant oil from refrigerant. |
Refrigerant |
Non-CFC/HCFC environmental friendly based on compressor capacity. |
Low Temperature Freezer Alarms |
Alarms |
Audio-video alarm system to warn of high or low temperature. Optional alarm systems like door ajar, condenser faults etc. Optional Alarm system with Rechargeable battery backup. |
Low Temperature Freezer Controls |
Temperature Controls |
Micro-processor based Temperature controller cum indicator. |
Data Recorder/logger
(Optional) |
Temperature chart recorder or data logger with software for storing data and downloading data to computer for storage & print. |
Computer Interface
(Optional) |
Temperature Controller with computer interface for computer based monitoring and data storage. Software is provided for monitoring and data recording. |
Memory & Print
(Optional) |
Memory for temperature data storage and printer port for printing stored data. |
High & Low alarms |
Audio-visual high & low temperature alarms. |
Optional |
Alarm system for various parameters with rechargeable battery backup; Voltage Safety System; Backup refrigeration system etc. |
Power Supply |
220 volts, 50Hz / 110 volts, 60Hz. |
|